The Midea M-Thermon A 6 (model MHC-V6W/D2N8-B2E30, code 14082172) is a monobloc air source heat pump from the Arctic range, designed for heating and cooling in homes and small commercial spaces with moderate thermal demand. It features R-32 refrigerant, wired control, and WiFi connectivity for remote management.
Important: The unit does not autonomously produce DHW (domestic hot water); to have DHW in the installation, an external tank/indirect tank is essential (not included), along with the corresponding hydraulic and control accessories.
Key Features
- Services: heating and cooling. DHW only with external tank.
- 100% water installation: only hydraulic connections to the outdoor unit (no refrigerant handling).
- High temperature supply: water up to 65 °C with +5 °C outdoor; up to 60 °C with −15 °C.
- Connectivity: WiFi (MSmartLife app), compatible with Amazon Alexa and Google Assistant.
- Cascade operation without special control to modulate power in multi-unit installations.
- Smart Grid Ready and USB Setup for fast parameterization and diagnostics.
- Zoning and BMS: compatible with Airzone/Acuazone; native Modbus RTU (BACnet/KNX via gateway).
- CTE 2020 / CYPE: considered renewable and listed in the CYPE database.
Performance (M-Thermon A 6)
- Heating A7/W35: 6.35 kW · COP 4.95
- Heating A7/W55: 6.0 kW · COP 2.95
- Heating A-7/W35: 6.00 kW · COP 3.00
- Heating A-7/W55: 5.15 kW · COP 2.05
- Cooling A35/W18: 6.5 kW · EER 4.8
- Cooling A35/W7: 7.0 kW · EER 3.0
- SCOP (average climate): 4.95 (W35) · 3.52 (W55)
- SCOP (warm climate): 6.63 (W35) · 4.19 (W55)
- SCOP (cold climate): 4.21 (W35) · 2.85 (W55)
- SEER (cooling): 5.34 (W7) · 8.21 (W18)
Operating Ranges and Temperatures
- Outdoor DHW: −25…+43 °C · Outdoor heating: −25…+35 °C
- Outdoor cooling: −5…+43 °C
- DHW service: 40…65 °C (via external tank)
- Heating service: 25…65 °C · Cooling service: 5…25 °C
Hydraulics and Integrated Components
- Water pump: available pressure 8.5 mwc
- Expansion vessel: 8 L
- Electric backup heater: 3,000 W
- Minimum system water volume: 40 L
- Nominal flow rate: 0.95 m³/h
- Hydraulic connections: 1″
Electrical and Acoustic Data
- Power supply: 220–240 V / 1 ph / 50 Hz
- Maximum current: 31 A · Recommended protection: D32 circuit breaker
- Sound pressure: 47.5 dB(A) · Sound power: 58 dB(A)
Refrigerant
- Type: R-32 · GWP: 675
- Charge: 1.4 kg · t CO₂ eq: 0.95 t
Dimensions and Weight
- Outdoor unit (W × H × D): 1,295 × 792 × 429 mm
- Net weight: 86 kg
Compatibility and Control
- Zoning: Airzone / Acuazone (underfloor heating, fan coils, radiators).
- Smart Home: MSmartLife app, Alexa, and Google Assistant.
- BMS: native Modbus RTU; integration with BACnet/KNX via gateway.
- Smart Grid Ready: prepared for external grid signal.
Required Components for DHW (not included)
- DHW tank/indirect tank with coil sized to demand.
- Tank sensor and 3-way valve for heating–DHW switching.
- Safety elements: safety valve, check valve, air vents, sanitary expansion vessel if needed.
- Thermostatic mixing valve to limit consumption temperature.
- Secondary circulator if required by the system hydraulics.
Recommended Applications
Well-insulated single-family homes, apartments, or commercial spaces with a thermal demand around 6 kW to 7 kW (A7/W35). The 100% water monobloc design simplifies regulatory compliance and reduces commissioning time thanks to USB configuration.
Installation and Maintenance
- Hydraulic supply/return connections; no refrigerant handling required.
- Maintain service distances, level and anti-vibration support.
- Size inertia and hydraulic balancing according to minimum flow/volume.
- Check wiring sections and protections according to the indicated maximum current.
Performance Summary
- Heating capacity: 6.35 kW (A7/W35) · 6.0 kW (A7/W55)
- Cooling capacity: 6.5 kW (A35/W18) · 7.0 kW (A35/W7)
- SCOP (average climate): 4.95 (W35) · 3.52 (W55)
- SEER: 8.21 (W18) · 5.34 (W7)
- DHW supply: up to 65 °C with external tank