The Midea M-Thermon A 4 (model MHC-V4W/D2N8-B2E30, code 14082171) is a monobloc air-to-water heat pump designed for heating and cooling in well-insulated homes with low thermal demand (around 4 kW at A7/W35). It features R-32 refrigerant, wired control, WiFi connectivity, and compatibility with zoning systems (Airzone, Acuazone) and BMS.
Important: The unit does not produce domestic hot water (DHW) autonomously; to have DHW in the installation, an external tank/indirect tank (not included) with the corresponding hydraulic and control accessories is essential.
Key Features
- Services: Heating and cooling. DHW only with external tank.
- 100% water installation: Only hydraulic supply/return (no refrigerant handling).
- High temperature supply: Water up to 65°C with +5°C outdoor; up to 60°C with −15°C.
- Connectivity: WiFi (MSmartLife app), compatible with Amazon Alexa and Google Assistant.
- Smart Grid Ready and cascade operation without special control for power modulation.
- USB Setup: Fast parameterization and diagnostics via USB port.
- Zoning and BMS: Native Modbus RTU; BACnet/KNX via gateway.
- CTE 2020 / CYPE: Considered a renewable solution and included in the CYPE database.
Performance (M-Thermon A 4)
- Heating A7/W35: 4.2 kW · COP 5.1
- Heating A7/W55: 4.4 kW · COP 2.95
- Heating A-7/W35: 4.70 kW · COP 3.10
- Heating A-7/W55: 4.00 kW · COP 1.95
- Cooling A35/W18: 4.5 kW · EER 5.5
- Cooling A35/W7: 4.7 kW · EER 3.45
- SCOP (average climate): 4.85 (W35) · 3.31 (W55)
- SCOP (warm climate): 6.52 (W35) · 4.14 (W55)
- SCOP (cold climate): 4.06 (W35) · 2.63 (W55)
- SEER (cooling): 4.99 (W7) · 7.77 (W18)
Operating Ranges and Temperatures
- Outdoor DHW: −25…+43°C · Outdoor heating: −25…+35°C
- Outdoor cooling: −5…+43°C
- DHW service: 40…65°C (via external tank)
- Heating service: 25…65°C · Cooling service: 5…25°C
Hydraulics and Integrated Components
- Water pump: Available pressure 8.5 mca
- Expansion vessel: 8 L
- Auxiliary electric heater: 3,000 W
- Minimum system water volume: 40 L
- Nominal flow rate: 0.70 m³/h
- Hydraulic connections: 1″
Electrical and Acoustic Data
- Power supply: 220–240 V / 1 ph / 50 Hz
- Maximum current: 31 A · Recommended protection: D20 A circuit breaker
- Sound pressure: 58 dB(A) · Sound power: 58 dB(A)
Refrigerant
- Type: R-32 · GWP: 675
- Charge: 1.4 kg · t CO₂ eq: 0.95 t
Dimensions and Weight
- Outdoor unit (W × H × D): 1,295 × 792 × 429 mm
- Net weight: 98 kg
Compatibility and Control
- Zoning: Airzone / Acuazone (underfloor heating, fan coils, radiators).
- Smart Home: MSmartLife app, Alexa, and Google Assistant.
- BMS: Native Modbus RTU; integration with BACnet/KNX via gateway.
- Smart Grid Ready: Ready for external grid signal.
Required Components for DHW (not included)
- DHW tank/indirect tank with coil sized to demand.
- Tank probe and 3-way valve for heating–DHW switching.
- Safety elements: safety valve, non-return valve, air vents, sanitary expansion vessel if required.
- Thermostatic mixing valve to limit consumption temperature.
- Secondary circulator if required by the system hydraulics.
Recommended Applications
Suitable for low-energy single-family homes or apartments with underfloor heating, fan coils, or low-temperature radiators. The 100% water monobloc design reduces paperwork and speeds up commissioning thanks to USB configuration.
Installation and Maintenance
- Hydraulic supply/return connections; no refrigerant handling required.
- Maintain service distances, level base, and anti-vibration elements.
- Size inertia and balancing according to minimum flow/volume.
- Check wiring sections and protections according to maximum current.
Performance Summary
- Heating capacity: 4.2 kW (A7/W35) · 4.4 kW (A7/W55)
- Cooling capacity: 4.5 kW (A35/W18) · 4.7 kW (A35/W7)
- SCOP: 4.85 (W35, average climate) · 3.31 (W55, average climate)
- SEER: 7.77 (W18) · 4.99 (W7)
- DHW supply: up to 65°C with external tank