The Midea M-Thermon A 14T (model MHC-V14W/D2RN8-B2ER90, code 14082179) is a three-phase monobloc air-to-water heat pump from the Arctic range, designed for heating and cooling in homes and buildings with a thermal demand of around 14.5 kW (A7/W35). It features R-32 refrigerant, wired control, WiFi connectivity, and compatibility with zoning systems and BMS.
Important: the unit does not produce domestic hot water (DHW) autonomously; to have DHW, an external tank/intertank is essential (not included) along with the corresponding hydraulic and control accessories.
Key Features
- Services: heating and cooling. DHW only with external tank.
- 100% water installation: only hydraulic connections (no gas handling).
- High temperature: water supply up to 65 °C with +5 °C outdoor; up to 60 °C with −15 °C.
- Connectivity: WiFi (MSmartLife app), compatible with Amazon Alexa and Google Assistant.
- Smart Grid Ready and cascade without special control.
- USB Setup: fast parameterization and diagnostics via USB port.
- Zoning and BMS: Airzone/Acuazone; native Modbus RTU (BACnet/KNX via gateway).
- CTE 2020 / CYPE: recognized as renewable and included in the CYPE database.
Performance (M-Thermon A 14T)
- Heating A7/W35: 14.5 kW · COP 4.6
- Heating A7/W55: 13.8 kW · COP 2.95
- Heating A-7/W35: 12.0 kW · COP 2.85
- Heating A-7/W55: 11.0 kW · COP 2.05
- Cooling A35/W18: 13.5 kW · EER 3.6
- Cooling A35/W7: 12.4 kW · EER 2.5
- SCOP (average climate): 4.72 (W35) · 3.47 (W55)
- SCOP (warm climate): 6.58 (W35) · 4.49 (W55)
- SCOP (cold climate): 4.07 (W35) · 3.05 (W55)
- SEER (cooling): 4.83 (W7) · 6.85 (W18)
Operating Ranges and Temperatures
- Outdoor DHW: −25…+43 °C · Outdoor heating: −25…+35 °C
- Outdoor cooling: −5…+43 °C
- DHW service: 40…65 °C (via external tank)
- Heating service: 25…65 °C · Cooling service: 5…25 °C
Hydraulics and Integrated Components
- Water pump: available pressure 8.5 mwc
- Expansion vessel: 8 L
- Electric backup heater: adjustable 9,000/6,000/3,000 W
- Minimum water volume: 60 L
- Nominal flow rate: 2.50 m³/h
- Hydraulic connections: 1 1/4″
Electrical and Acoustic Data
- Power supply: 380–415 V / 3 ph / 50 Hz
- Maximum current: 27 A · Recommended protection: D32 circuit breaker
- Sound pressure: 54 dB(A) · Sound power: 65 dB(A)
Refrigerant
- Type: R-32 · GWP: 675
- Charge: 1.75 kg · t CO₂ eq: 1.18 t
Dimensions and Weight
- Outdoor unit (W × H × D): 1,385 × 945 × 526 mm
- Net weight: 172 kg
Compatibility and Control
- Zoning: Airzone / Acuazone (underfloor heating, fan coils, radiators).
- Smart Home: MSmartLife app, Alexa, and Google Assistant.
- BMS: native Modbus RTU; integration with BACnet/KNX via gateway.
- Smart Grid Ready: prepared for external grid signal.
Required Components for DHW (not included)
- DHW tank/intertank with coil sized to demand.
- Tank probe and 3-way valve for heating–DHW switching.
- Safety elements: safety valve, non-return valve, air vents, sanitary vessel if required.
- Thermostatic mixing valve to limit consumption temperature.
- Secondary circulator if required by the system hydraulics.
Recommended Applications
Larger single-family homes, compact technical rooms, and projects with three-phase supply. The 100% water monobloc design facilitates regulatory compliance and speeds up commissioning via USB configuration.
Installation and Maintenance
- Hydraulic supply/return connections; no refrigerant handling required.
- Maintain service distances, level base, and anti-vibration elements.
- Size inertia and balancing according to minimum flow/volume.
- Check wiring sections and protections according to maximum current.
Performance Summary
- Heating capacity: 14.5 kW (A7/W35) · 13.8 kW (A7/W55)
- Cooling capacity: 13.5 kW (A35/W18) · 12.4 kW (A35/W7)
- SCOP: 4.72 (W35, average climate) · 3.47 (W55, average climate)
- SEER: 6.85 (W18) · 4.83 (W7)
- DHW supply: up to 65 °C with external tank