The Midea M-Thermon A 14 (model MHC-V14W/D2N8-B2E30, code 14082176) is a monobloc air source heat pump from the Arctic range, designed for heating and cooling medium to large residential and commercial spaces. It features R-32 refrigerant, standard wired control, WiFi connectivity, and compatibility with zoning solutions (Airzone, Acuazone) and BMS (Modbus RTU; BACnet/KNX via gateway).
Important: DHW production is not autonomous in the unit; to have DHW in the installation, an external tank/intertank (not included) and the corresponding hydraulic and control accessories are essential.
Key Features
- Services: heating and cooling. DHW only with external tank.
- 100% water installation: only hydraulic connections on the outdoor unit.
- High temperature supply: water up to 65°C with +5°C outdoor; up to 60°C with −15°C.
- Connectivity: WiFi (MSmartLife app), Amazon Alexa, and Google Assistant.
- Smart Grid Ready and cascade operation without special control to modulate power.
- USB Setup: fast parameterization and diagnostics via USB port.
- Zoning compatibility: Airzone/Acuazone (up to 32 services).
- Regulatory compliance: considered renewable (CTE 2020) and included in CYPE database.
Performance (M-Thermon A 14)
- Heating A7/W35: 14.5 kW · COP 4.6
- Heating A7/W55: 13.8 kW · COP 2.95
- Heating A-7/W35: 12.0 kW · COP 2.85
- Heating A-7/W55: 11.0 kW · COP 2.05
- Cooling A35/W18: 13.5 kW · EER 3.6
- Cooling A35/W7: 12.4 kW · EER 2.5
- SCOP (average climate): 4.72 (W35) · 3.47 (W55)
- SCOP (warm climate): 6.58 (W35) · 4.49 (W55)
- SCOP (cold climate): 4.07 (W35) · 3.05 (W55)
- SEER (cooling): 4.86 (W7) · 6.85 (W18)
Operating Ranges and Temperatures
- Outdoor DHW: −25…+43°C · Outdoor heating: −25…+35°C
- Outdoor cooling: −5…+43°C
- DHW service: 40…65°C (via external tank)
- Heating service: 25…65°C · Cooling service: 5…25°C
Hydraulics and Integrated Components
- Water pump: 8.5 mca (available pressure)
- Expansion vessel: 8 L
- Auxiliary electric heater: 3,000 W
- Minimum system water volume: 60 L
- Nominal flow rate: 2.50 m³/h
- Hydraulic connections: 1 1/4″
Electrical and Acoustic Data
- Power supply: 220–240 V / 1 ph / 50 Hz
- Maximum current: 43 A · Recommended protection: D45 circuit breaker
- Sound pressure: 53.5 dB(A) · Sound power: 65 dB(A)
Refrigerant
- Type: R-32 · GWP: 675
- Charge: 1.75 kg · t CO₂ eq: 1.18 t
Dimensions and Weight
- Outdoor unit (W × H × D): 1,385 × 945 × 526 mm
- Net weight: 155 kg
Compatibility and Control
- Airzone / Acuazone: zoning for underfloor heating, fan coils, and radiators.
- Smart Home: MSmartLife app, Alexa, and Google Assistant.
- BMS: Native Modbus RTU; integration with BACnet/KNX via gateway.
- Smart Grid Ready: prepared for external grid signal.
Required Components for DHW (not included)
- DHW tank/intertank with coil sized to demand.
- Tank probe/thermistor and 3-way valve for heating–DHW switching.
- Safety elements: safety valve, non-return valve, purge, sanitary vessel if required.
- Thermostatic mixing valve for safe consumption temperatures.
- Secondary circulator if required by system hydraulics.
Recommended Applications
Single-family or multi-family homes, boiler replacement renovations, and multi-zone projects. The monobloc design reduces paperwork as it is a 100% water installation and speeds up commissioning via USB configuration.
Installation and Maintenance
- Hydraulic supply/return connection, no refrigerant handling required.
- Maintain service distances and a stable surface to minimize vibrations.
- Size hydraulic inertia and balancing according to minimum flow/volume.
- Check wiring sections and protections according to maximum current.
Performance Summary
- Heating capacity: 14.5 kW (A7/W35) · 13.8 kW (A7/W55)
- Cooling capacity: 13.5 kW (A35/W18) · 12.4 kW (A35/W7)
- SCOP: 4.72 (W35, average climate) · 3.47 (W55, average climate)
- SEER: 6.85 (W18) · 4.86 (W7)
- DHW supply: up to 65°C with external tank